Infusion Pump KIP–A100

Download Catalog

Infusion Pump KIP–A100

Infusion Pump KIP–A100

Description:

Infusion Pump KIP–A100 is a single-channel light–weight, drip-type volumetric fluid delivery system. Digitally driven fluid-control, automated calibration and dose titration enhances safety. Peristaltic pumping mechanism ensures precise flow-measurement and prevents back-flow of IV fluid. Backlit display enables suitably ambient illumination to operate even at low light condition.

Specifications :

Accuracy Flow rate: ≤ ± 3 %
Mechanical: ≤ ± 2 %
Battery 11.1 V rechargeable Li-ion battery; > 2000 mAh
Works more than 4 hours at 25 ml/h after charging for 8 hours
Bolus 10 ml/h ~ 1200 ml/h at 0.1 ml/h (flow rate < 100 ml/h)
10 ml/h ~ 1200 ml/h at 1 ml/h (flow rate > 100 ml/h)
Channel Single channel infusion
Dimensions 188 x 198 x 228 mm
Display 4.3-inch colour LCD with backlight
Drop Rate 1 drop/min ~ 400 drops/min (1 drop/min increment)
Drug Library Database of up to 210 drugs
Environmental Condition : Operation Operating temperature 5 ⁰C ~ 40 ⁰C
Operating humidity 20 % ~ 90 %
Environmental Condition: Storage Storage temperature -10 ⁰C ~ 55 ⁰C
Storage humidity 10 % ~ 90 %
Fuse F1AL / 250 V
Infusion Rate 1.0 ml/h ~99.9 ml/h (0.1 ml/h increment)
100 ml/h ~1200 ml/h (1 ml/h increment)
KVO Rate 1 ml/h (1 ml/h ~ 300 ml/h)
3 ml/h (greater than 300 ml/h)
Memory Up to 1500 record entries
Occlusion System 3 selectable occlusion levels
Occlusion Threshold High: 800 mmHg ± 200 mmHg (106.7 kPa ± 26.7 kPa)
Medium: 500 mmHg ± 100 mmHg (66.7 kPa ± 13.3 kPa)
Low: 300 mmHg ± 100 mmHg (40.7 kPa ± 13.3 kPa)
Power Supply AC 85 ~ 265 V, 50/60 Hz, < 40 VA
Purge 800 ml/h
Sensitivity [Bubble detection] > 25 μL
Therapy Timer Range 1 min ~ 9999 min ( 1 min increment)
Volume (VTBI) 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Weight 2.5 Kgs
Features:
Infusion Modes - Rate mode, Time mode, Volume mode
Automated calibration
Provision for infusion fluid warming
Built-in drug database library
Suitable for all brands of IV set
Alarm: Infusion Complete, Occlusion, Door Open, Air Bubble,
Low Battery, Setting Error, Power failure, Stand-by
Applications:
Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy.
Nano Med
  • Guangzhou Nano Medical Equipment Co., Ltd. 407, No. 1 Qingbu Street, Xinya Street, Huadu District, Guangzhou, Guangdong, China
  • Email:info@nanomed.cc | www.nanomed.cc