Anaesthesia System KAM-B100

Download Catalog

Anaesthesia System KAM-B100

Anaesthesia System KAM-B100

Description:

Anaesthesia System KAM-B100 is fully featured high-end general anaesthesia workstation equipped with wide screen display for respiratory trends, and other vital parameters. PCV and SIMV + PS modes ensure flexible ventilation. Comprehensive monitoring and intelligent gas flush and cut-off system for critical events improves patient safety.

Specifications :

Alarm High/Low Airway Pressure, Sustained Airway Pressure, High/Low Minute Volume, High/Low FiO2, High Breath Rate, O2 supply failure, Power failure, Apnea alarm, Mute : 110s
Anaesthetic Agents Halothane, Enflurane, Isoflurane, Sevoflurane
APL Range Spontaneous breathing (SP) -70 cmH2O
Battery 24 V 4Ah ; 120 min
CO2 Absorption Tank 3 L Autoclavable
Dimensions 760 × 1300 × 630mm
Display 10.4” TFT Colour
Drive Pneumatically driven and electronically controlled
Electronic PEEP Off / 3 cmH2O – 30 cmH2O
Flowmeter O2 : 0 ~ 10L/min
Air : 0 ~ 12L/min
N2O : 0 ~ 10L/min
Auxiliary O2 : 0 ~ 12L/min
Gas Supply O2 , Air, N2O
Graph Display P-T, F-T, P-V, F-V
I: E Ratio 4:1 to 1:8
Operational modes Closed, Semi-closed, Semi-open
Plateau (Inspiratory) Off / 5% – 60% Ti
Power Supply 100 V ~ 240 V 50/60 Hz
Pressure (Inspiratory) 5 cmH2O – 70 cmH2O
Pressure (Support) 3 cmH2O – 50 cmH2O
Pressure Trend Paw, Ppeak, Pplat, Pmean, PEEP
T-slope 0 ~ 2s
Tidal Volume 20 ml to 1500 ml
Trigger Sensitivity 1 – 15 L/min
Vaporizer Supports 2 vaporizers
Vaporizer Filling methods Pour Fill
Key Fill
Quick-Fil
Ventilation Gas (Optional CO2, AG, MAC) FiO2
Ventilation Modes IPPV, PCV, SIMV + PS, PS and Manual
Ventilator Pressure at Inlet 280 kPa ~ 600 kPa
Volume Monitoring MV, VT, Freq
Weight 100 Kgs
Features:
Integrated 10.4” Monitor screen
Ventilation modes: IPPV, PCV, SIMV + PS, PS and Manual
CO2 Absorption: 3 Litre Autoclavable Tank
Flowmeter: minimum 25% O2/N2O mixture concentration
Double Vaporizer with Selectatec interlock
Comprehensive safety alarms with mute
Suitable for central or non-central OT
Suitable for Adult, Pediatric and Infant
Monitoring of O2, CO2 and anaesthetics (optional)
Heated Breathing system (optional)
Applications:
Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.
Nano Med
  • Guangzhou Nano Medical Equipment Co., Ltd. 407, No. 1 Qingbu Street, Xinya Street, Huadu District, Guangzhou, Guangdong, China
  • Email:info@nanomed.cc | www.nanomed.cc